Summary for Test 2021-11-11-26-2
Test performed: AASHTO T59-16Project Information
| Project Identifiers | Project ID: 215348 DEA: 060U4204 EFIS: 0616000004 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-99-R4.9/11.6 |
| Award Date | 02/25/2021 |
| Closeout Date | 12/02/2025 |
| Work Description | CONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION. |
| Location Description | FRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING |
| QA Service Level | 1 (Verified on 12/07/2020) |
Sample Information
| Sample Taken Date | 11/11/2021 | Sample Unique Key | 26 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/03/2021 | Sample type | Department Acceptance |
| A brief description of the sample | SS-1H 1jug emulsion | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Source | First name of sampler or witnessed by | Donald |
| Last name of sampler or witnessed by | HIURR | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Talley Oil - Madera | |
| Transportation Laboratory (TL) Number | 027630 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | SS-1h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | Not set |
Test Details
DIME Sample ID: 2021-11-11-26
DIME Test ID: 2021-11-11-26-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2021-12-07
Test Results
How many beakers will be used to conduct the test?: 4
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 12/07/2021
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 452.1 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 424.4 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 451.9 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 423.9 g
Beaker 3 Mass of beaker, rod, screen (if used), and residue: 449.9 g
Beaker 3 Tare mass of the beaker, rod, and screen (if used): 421.9 g
Beaker 4 Mass of beaker, rod, screen (if used), and residue: 446.0 g
Beaker 4 Tare mass of the beaker, rod, and screen (if used): 418.1 g
Beaker 1 Residue: 55.4 %
Beaker 2 Residue: 56.0 %
Beaker 3 Residue: 56.0 %
Beaker 4 Residue: 55.8 %
Percentage of residue: 56 %
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 12/7/2021 ✔