Summary for Test 2021-10-26-3-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 215164
DEA: 07317304
EFIS: 0715000237
DIST-CO-RTE-PM07-LA-60-0.0/R3.2,11.8/R21.5
Award DateNot set
Closeout Date08/01/2023
Work DescriptionUPGRADE EXISTING OVERHEAD AND ROADSIDE SIGN PANELS.
Location DescriptionLOS ANGELS COUNTY FROM 0.4 MILE WEST OF ROUTE 5/60 SEPARATION TO ROUTE 60/710 SEPARATION AND FROM ROUTE 60/605 SEPARATION TO FAIRWAY DRIVE UNDERCROSSING
QA Service Level1 (Verified on 02/18/2021)

Sample Information

Sample Taken Date10/26/2021 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing11/02/2021 Sample typeQuality Assurance
A brief description of the sample(16) #14 ZAP Coupler The quantity of what the sample constitutes(16) #14 ZAP Coupler
From where was the sample collectedFabricator First name of sampler or witnessed byRigoberto
Last name of sampler or witnessed byMarin Title of samplerAMR
Telephone number of sampler9515000685 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCamblin Steel Service
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL133-123-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerDouble Row ZAP Screwlok Type 2 Series Intermediate Assembler or FabricatorCamblin Steel
Rebar Size#14 Coupler ModelDouble Zap Screwlok Type 2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)MM20106095 Rebar Heat Number(s)9002146
Rebar Size 2 14 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-10-26-3
DIME Test ID: 2021-10-26-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2021-12-02

Test Results


Number of Samples: 4
Input Type: Calculated
Tester's full name: She Vang
Date of test: 11/18/2021
UTM: NA
Halo ID: Smith Emery Laboratory
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11MM20106095#142.250.00921692096410Service SpliceChoi
22MM20106095#142.25019489086620Service SpliceChoi
33MM20106095#142.25022380099470Service SpliceChoi
44MM20106095#142.250225630100280Service SpliceChoi

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/2/2021 ✔