Summary for Test 2016-02-11-4-7

Test performed: SMTL BILST-06

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/11/2016 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/12/2016
Sample typeQuality Assurance A brief description of the sampleJoint Seal
The quantity of what the sample constitutes600ft From where was the sample collectedSource
First name of sampler or witnessed byDavid Last name of sampler or witnessed bySimon
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWatson Bowman Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM2 - Type B Elastomeric Joint Seal Mfg. Lot Number(s)0116127
Manufacturer(s)Watson Bowman Temperature72
Humidity50 CommentsUnknown
Joint Seal Size5.00in

Test Details

DIME Sample ID: 2016-02-11-4
DIME Test ID: 2016-02-11-4-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Test Release Date: 2016-02-25

Test Results


Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 02/23/2016
Result: Pass
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/25/2016