Summary for Test 2021-11-11-11-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 214099 DEA: 024F5904 EFIS: 0213000010 |
|---|---|
| DIST-CO-RTE-PM | 02-TEH-5-R25.4 |
| Award Date | 07/08/2020 |
| Closeout Date | 08/14/2023 |
| Work Description | BRIDGE SEISMIC RETROFIT AND SCOUR REPAIR. |
| Location Description | TEHAMA COUNTY IN RED BLUFF AT SACRAMENTO RIVER BRIDGE |
| QA Service Level | 1 (Verified on 05/07/2019) |
Sample Information
| Sample Taken Date | 11/11/2021 | Sample Unique Key | 11 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/18/2021 |
| Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
| The quantity of what the sample constitutes | 71 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpenter |
| Title of sampler | QA | Telephone number of sampler | 14156081742 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Nucor | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-109-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 447030AR |
|---|---|---|---|
| Heat Number(s) | 100205634 | Nut Mfg. Lot Number(s) | 453592B |
| Washer Mfg. Lot Number(s) | 10618 | Bolt Specification | A325 |
| Bolt Length(s) | 2-3/4" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 447030A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2021-11-11-11
DIME Test ID: 2021-11-11-11-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-12-02
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 11/23/2021
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 453592B | 72630 | Nut Proof Load | spaine |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 12/2/2021 ✔