Summary for Test 2016-02-15-2-1
Test performed: CTM 673-July 2012Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/15/2016 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/16/2016 |
Sample type | Quality Assurance | A brief description of the sample | Joint Seal |
The quantity of what the sample constitutes | 500ft | From where was the sample collected | Source |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Simon |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Watson Bowman | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM2 - Type B Elastomeric Joint Seal | Mfg. Lot Number(s) | 0216134 |
---|---|---|---|
Manufacturer(s) | Watson Bowman | Temperature | 72 |
Humidity | 50 | Comments | Unknown |
Joint Seal Size | 2.75in |
Test Details
DIME Sample ID: 2016-02-15-2
DIME Test ID: 2016-02-15-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 673-July 2012: Method of Determining Movement Rating of Type B1 and B2 Preformed Elastomeric Joint Seals
Test Release Date: 2016-02-25
Test Results
Input Type: Measured
Tester's full name: Brian
Date of test: 02/17/2016
UTM: 11KIP
Temperature: 72 ?F
Humidity: 50 %
Load at W1: 55.1108 lbs
Width at 4 x Load at W1: 1.24143 in
Nominal Width: 2.75 in
Measured Maximum Uncompressed Width: 2.937 in
Measured Minimum Uncompressed Width: 2.8945 in
Minimum Uncompressed Width as Specified by the Manufacturer (MUWASBM): 2.853 in
Height of Contact Face: 2.8975 in
Length: no data
Spec Minimum Uncompressed Width: 2.853 in
Area (5 Times of the Height of Contact Face): 14.488 sqin
Half of the Spec Minimum Uncompressed Width: 1.4265 in
85 Percent of the Spec Minimum Uncompressed Width: 2.42505 in
3 Times of the Area: 43.464 sqin
4 Times of the Load at W1: 220.443 in
W1 (US Units): 2.425 in
W1 (Metric Units): 61.596 millimeters
W2 (US Units): 1.241 in
W2 (Metric Units): 31.532 millimeters
Satisfactory of MR of (US Units): 1.184 in
Satisfactory of MR of (Metric Units): 30.064 millimeters
Optional W1 Measurement 1: 2.4603 in
Optional W1 Measurement 2: 43.7538 sqin
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 2/25/2016 ✔