Summary for Test 2021-10-27-13-2

Test performed: AASHTO T30-19

Project Information

Project IdentifiersProject ID: 215704
DEA: 020J9104
EFIS: 0219000174
DIST-CO-RTE-PM02-LAS,MOD,SHA-89,139,299-VAR
Award Date06/03/2021
Closeout Date08/08/2022
Work DescriptionREPAIR UNSOUND CONCRETE, POLYESTER CONCRETE OVERLAYS, JOINT SEALS.
Location DescriptionLASSEN, MODOC, AND SHASTA COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 05/03/2021)

Sample Information

Sample Taken Date10/27/2021 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing10/27/2021 Sample typeDepartment Acceptance
A brief description of the sampleLime Treated 3/4-inch Type A Aggregate The quantity of what the sample constitutesProduction Start-Up Evaluation
From where was the sample collectedManufacturer First name of sampler or witnessed byCindy
Last name of sampler or witnessed byBryant Title of samplerTET
Telephone number of sampler Laboratory sample identificationD78967
Linked DIME Sample ID2021-10-27-10, 2021-10-27-12 The fabricator/manufacturer/facility nameJF Shea Construction - Fawndale Rock and Asphalt - Redding, CA
Transportation Laboratory (TL) Number875743 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0017
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedMathematically Combined
Where the material sample would have been placed if not sampled02 MOD LAS SIS SHA VAR Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-10-27-13
DIME Test ID: 2021-10-27-13-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2021-11-18

Test Results


Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Calculated
Tester's full name: Darrell Valasek
Date of test: 11/03/2021
Cumulative Percent Passing
100 %
100 %
100 %
100 %
87 %
76 %
53 %
34 %
22 %
15 %
11 %
8 %
6.0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/18/2021 ✔