Summary for Test 2015-11-20-6-1
Test performed: CTM 213-December 2012Project Information
| Project Identifiers | Project ID: 209686 DEA: 062HT114 EFIS: 0615000257 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-99-23.5-26.7 |
| Award Date | 10/16/2015 |
| Closeout Date | 03/10/2021 |
| Work Description | Project 0615000257 (EA 06-2HT11) is a subset of the 0612000287 (06-2HT10). Together, both Project IDs comprise the SR 99 Realignment project. Per project PM, METS shall charge all their time related to the Realignment project to 06-2HT10. |
| Location Description | Early Work Portion only; McKinley Ave and Motel Dr under-crossings, six retaining walls, improvements to local/frontage roads and infrastructure in advance of High Speed Rail. |
| QA Service Level | 1 (Verified on 06/16/2014) |
Sample Information
| Sample Taken Date | 11/20/2015 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/22/2016 |
| Sample type | Annual Source Testing | A brief description of the sample | Fine PCC Aggregate |
| The quantity of what the sample constitutes | 6 bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | Holdridge |
| Title of sampler | TET | Telephone number of sampler | Unknown |
| Laboratory sample identification | 16FPCC-0050 | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Vulcan Sanger | Transportation Laboratory (TL) Number | C812120D |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0010 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Stockpile |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
| The concrete mix design number | Lot number | Not set | |
| Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2015-11-20-6
DIME Test ID: 2015-11-20-6-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 213-December 2012: Method of Test for Organic Impurities in Concrete Sand
Test Release Date: 2016-02-25
Test Results
Input Type: Calculated
Tester's full name: Tom Stinnett
Date of test: 02/16/2016
Is the sample satisfactory or not?: Yes
Does debris exist: No
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/25/2016 ✔