Summary for Test 2021-09-16-46-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214919
DEA: 060U4504
EFIS: 0615000298
DIST-CO-RTE-PM06-FRE-168-18.6/T25.5
Award Date06/16/2020
Closeout Date07/29/2022
Work DescriptionCOLD PLANE AC PAVEMENT AND HOT MIX ASPHALT RESURFACING.
Location DescriptionFRESNO COUNTY NEAR PRATHER FROM 0.1 MILE EAST OF SAMPLE ROAD TO OAK CREEK ROAD
QA Service Level1 (Verified on 04/21/2020)

Sample Information

Sample Taken Date09/16/2021 Sample Unique Key46
Date that the sample was received by the laboratory/organization performing the testing11/04/2021 Sample typeDispute Resolution
A brief description of the sample1/2 RHMA-G The quantity of what the sample constitutes4 boxes
From where was the sample collectedManufacturer First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identification021-060
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMI Fresno
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormC027593
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number2
Sublot number1 HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2021-09-16-46
DIME Test ID: 2021-09-16-46-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-11-18

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Glenn Bradley
Date of test: 11/18/2021
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1710.2 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1581.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.03 %
Moisture Content: 0.20 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 7.27 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/18/2021 ✔