Summary for Test 2021-11-02-28-1

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 215424
DEA: 024G4404
EFIS: 0214000013
DIST-CO-RTE-PM02-SIS-3-38.0/38.6
Award Date04/05/2021
Closeout Date08/14/2023
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD
QA Service Level1 (Verified on 01/19/2021)

Sample Information

Sample Taken Date11/02/2021 Sample Unique Key28
Date that the sample was received by the laboratory/organization performing the testing11/02/2021 Sample typeDepartment Acceptance
A brief description of the sampleLime Treated 3/4-inch Type A HMA (eq. PG 64-28 M) with 22.0% RAP and virgin PG 58-34 M from Valero - Benicia The quantity of what the sample constitutesProduction Start-Up Evaluation
From where was the sample collectedManufacturer First name of sampler or witnessed byClint
Last name of sampler or witnessed byRogers Title of samplerPI
Telephone number of sampler Laboratory sample identificationD78970
Linked DIME Sample ID The fabricator/manufacturer/facility nameTullis - Northstate Asphalt - Redding, CA
Transportation Laboratory (TL) Number853085 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2021-11-02-28
DIME Test ID: 2021-11-02-28-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-11-19

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 11/03/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7336.5 grams
Mass of oven-dry sample in air for Sample 1: 2653.2 grams
Mass of container filled with the sample and water for Sample 1: 8937.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.523
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/19/2021 ✔