Summary for Test 2015-11-18-6-1

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 210369
DEA: 042J2004
DIST-CO-RTE-PM04-SCL-152-30.4/35.2
Award Date05/29/2015
Closeout Date12/22/2017
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE RUBBERIZED HOT MIX ASPHALT.
Location DescriptionSANTA CLARA COUNTY 20 MILES EAST OF GILROY FROM PACHECO CREEK TO SANTA CLARA / MERCED COUNTY LINE
QA Service Level1 (Verified on 09/17/2015)

Sample Information

Sample Taken Date11/18/2015 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing01/21/2016 Sample typeAnnual Source Testing
A brief description of the sample3/8 PCC Aggregate The quantity of what the sample constitutes3 bags
From where was the sample collectedSource First name of sampler or witnessed byCesar
Last name of sampler or witnessed byRamirez Title of samplerConsultant
Telephone number of samplerUnknown Laboratory sample identification16CPCC-0027
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTriangle Rock Los Banos
Transportation Laboratory (TL) Numberc931556 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-24-0009
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2015-11-18-6
DIME Test ID: 2015-11-18-6-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2016-02-25

Test Results


What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Tom Stinnett
Date of test: 02/16/2016
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 7.7 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/25/2016 ✔