Summary for Test 2021-10-28-4-7
Test performed: ASTM E18-15Project Information
| Project Identifiers | Project ID: 213598 DEA: 051F75U4 EFIS: 0518000092 |
|---|---|
| DIST-CO-RTE-PM | 05-MON-101-R36.9/47.7 |
| Award Date | 01/16/2019 |
| Closeout Date | 01/11/2024 |
| Work Description | CRCP, SEISMIC RETROFIT, BRIDGE WIDENING AND MEDIAN BARRIER |
| Location Description | MONTEREY COUNTY IN AND NEAR KING CITY FROM 0.4 MILE SOUTH OF WILD HORSE ROAD OVERCROSSING TO TEAGUE AVENUE |
| QA Service Level | 1 (Verified on 10/11/2018) |
Sample Information
| Sample Taken Date | 10/28/2021 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/05/2021 | Sample type | Quality Assurance |
| A brief description of the sample | ASTM A325 Assembly | The quantity of what the sample constitutes | 300 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Kevin |
| Last name of sampler or witnessed by | Couch | Title of sampler | METS Rep |
| Telephone number of sampler | 5304170632 | Laboratory sample identification | |
| Linked DIME Sample ID | 2021-10-28-2 | The fabricator/manufacturer/facility name | Tru-fit Products of Utah |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | Salinas River Bridge | |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | A46122 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | 1115-134 | Bolt Specification | n/a |
| Bolt Length(s) | Nut Specification | n/a | |
| Washer Specification | ASTM F436 | Finish | Mech Galv |
| Diameter/Size | 7/8 dia | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2021-10-28-4
DIME Test ID: 2021-10-28-4-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Test Release Date: 2021-11-18
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 11/17/2021
Sample No.: 1B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 1115-134
Finish Coating: ASTM B695 - Mech Galv
Product Markings: TSI F436
Size: .875 in
Bolt Length: no data
Hardness Reading Scale: C Scale
Spacing: Ok
Hardness Reading Average: 41.2
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/18/2021 ✔