Summary for Test 2021-11-04-2-1
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 215255 DEA: 040A7714 EFIS: 0420000287 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-80-6.4-6.6 |
| Award Date | 05/03/2021 |
| Closeout Date | 12/01/2023 |
| Work Description | CONSTRUCT PEDESTRIAN OVERCROSSING BRIDGE AND RETAINING WALLS. GILMAN INTERCHANGE IMPROVEMENTS |
| Location Description | ALAMEDA COUNTY IN BERKELEY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.1 MILE SOUTH OF GILMAN STREET UNDERCROSSING |
| QA Service Level | 1 (Verified on 12/07/2020) |
Sample Information
| Sample Taken Date | 11/04/2021 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/08/2021 | Sample type | Quality Assurance |
| A brief description of the sample | #5 HRC 120 T Head | The quantity of what the sample constitutes | 11 (Lot 1) |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Brian |
| Last name of sampler or witnessed by | Murray | Title of sampler | QA Inspector |
| Telephone number of sampler | 213 435 4055 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | HRC Fountain Valley | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-243-21 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 4111735 | Head Manufacturer Lot Number(s) | 10021114224 |
| Rebar Size | #5 | Headed Bar Model Name | HRC 120 |
| Size of Head | Reduced Size - 4x | Head Connection Type | Friction Weld |
| Head Shape | Square | Rebar Manufacturer | CMC Rebar |
| Head Manufacturer | Nucor | Head Fabricator | Nucor |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2021-11-04-2
DIME Test ID: 2021-11-04-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-11-10
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 11/10/2021
UTM: 400kip
Temperature: 72 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 0.31 | 29848 | 96283 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 11/10/2021 ✔