Summary for Test 2016-01-22-3-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 209139 DEA: 071170U4 EFIS: 0700000085 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10-33.2/37.2 |
| Award Date | 02/10/2014 |
| Closeout Date | 03/01/2022 |
| Work Description | CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS. |
| Location Description | LOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE WEST OF PUENTE AVENUE UNDERCROSSING TO 0.2 MILE EAST OF HOLLENBECK STREET UNDERCROSSING |
| QA Service Level | 1 (Verified on 05/06/2014) |
Sample Information
| Sample Taken Date | 01/22/2016 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/26/2016 | Sample type | Quality Control |
| A brief description of the sample | 6X12 | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | RYAN |
| Last name of sampler or witnessed by | RAMOS | Title of sampler | ASR |
| Telephone number of sampler | Unknown | Laboratory sample identification | 882-07 |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | HOLLIDAY |
| Transportation Laboratory (TL) Number | 101068907 | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | ROUTE 10 WEST COVINA | Structure name | HOLLENBECK AVE UC LT DECK POUR |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | CM5856 |
|---|---|---|---|
| The truck number from where the sample was collected | 647 | The batch plant ticket number from where the sample was collected | 101068907 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | TRUCK | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-01-22-3
DIME Test ID: 2016-01-22-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-02-01
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 02/01/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.97 in
Maximum load on cylinder 1: 166810 lb
Maximum load on cylinder 2: 171550 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 10 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 27.99 in^2
Compressive strength of cylinder 1: 5959.6 psi
Compressive strength of cylinder 2: 6129.0 psi
Compressive strength (to nearest 10 psi): 6040 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/1/2016 ✔