Summary for Test 2016-01-13-1-2

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date01/13/2016 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing01/15/2016 Sample typeQuality Assurance
A brief description of the sample.6in Prestressing Strand The quantity of what the sample constitutes7
From where was the sample collectedSource First name of sampler or witnessed byGino
Last name of sampler or witnessed byDel Chiaro Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameSumiden Wire
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsUnknown
Reel/Coil/Pack Number(s)S333569-2 S377355-5 Number of Coils2
Group NumberNA Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0536215-2 S0591115 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden

Test Details

DIME Sample ID: 2016-01-13-1
DIME Test ID: 2016-01-13-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2016-01-19

Test Results


Number of Samples: 4
Input Type: Calculated
Tester's full name: Brian
Date of test: 01/18/2016
UTM: 120KIP
Temperature: 70 F
Extensometers: E88766
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1SO536215-2S333569-20.217590665453227.81.73Brian
2SO536215-2S333569-20.2175934028.21.89Brian
3SO591115S377355-50.2175963727.81.75Brian
4SO591115S377355-50.2175973227.61.8Brian

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 1/19/2016 ✔