Summary for Test 2021-10-26-2-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 215164
DEA: 07317304
EFIS: 0715000237
DIST-CO-RTE-PM07-LA-60-0.0/R3.2,11.8/R21.5
Award DateNot set
Closeout Date08/01/2023
Work DescriptionUPGRADE EXISTING OVERHEAD AND ROADSIDE SIGN PANELS.
Location DescriptionLOS ANGELS COUNTY FROM 0.4 MILE WEST OF ROUTE 5/60 SEPARATION TO ROUTE 60/710 SEPARATION AND FROM ROUTE 60/605 SEPARATION TO FAIRWAY DRIVE UNDERCROSSING
QA Service Level1 (Verified on 02/18/2021)

Sample Information

Sample Taken Date10/26/2021 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing11/02/2021 Sample typeQuality Assurance
A brief description of the sample(16) #6 ZAP Coupler The quantity of what the sample constitutes(16) #6 ZAP Coupler
From where was the sample collectedFabricator First name of sampler or witnessed byRigoberto
Last name of sampler or witnessed byMarin Title of samplerAMR
Telephone number of sampler9515000685 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCamblin Steel Service
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL133-122-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCmc
Coupler ManufacturerSingle Row ZAP Screwlok Type 2 Series Intermediate Assembler or FabricatorCamblin Steel
Rebar Size#6 Coupler ModelZap Screwlok Type 2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)74117560 Rebar Heat Number(s)4111931
Rebar Size 2 6 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-10-26-2
DIME Test ID: 2021-10-26-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-11-03

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 11/03/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 6/19mm100.4444377100857Service Splicefsaylor

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 11/3/2021 ✔