Summary for Test 2015-12-29-4-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Award Date11/27/2012
Closeout Date02/12/2025
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
QA Service Level1 (Verified on 10/29/2012)

Sample Information

Sample Taken Date12/29/2015 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing12/29/2015 Sample typeQuality Assurance
A brief description of the sampleFlat Bar The quantity of what the sample constitutes2
From where was the sample collectedJob Site First name of sampler or witnessed byDong
Last name of sampler or witnessed byJun Shin Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameKyungin Industries
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Steel Check Sample Plate Heat Number(s)416820 , 141231
Material SpecificationA36 Grade36
Thickness4.5mm 3mm ShapeFlat Bar
Metal Foundry Manufacturer (Mill)Korea Steel Sangwon Steel Plate Dimension25mm x 12in

Test Details

DIME Sample ID: 2015-12-29-4
DIME Test ID: 2015-12-29-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Flat Sample)
Test Release Date: 2016-01-07

Test Results


Number of Samples: 2
Input Type: Calculated
Tester's full name: Fred
Date of test: 01/05/2016
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberWidth (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Total Elongation (%)Tested By
11412310.5050.0571515537271531.3Fred
24168200.5050.0864493246503537.2Fred

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 1/7/2016 ✔