Summary for Test 2021-10-26-6-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 993322
DEA: 010L4204
EFIS: 0122000008
DIST-CO-RTE-PM01-MEN,MEN/MEN-101-4/6, 4.0/6.0
Award Date08/23/2021
Closeout DateNot set
Work DescriptionLandslide Repair near Commisky
Location DescriptionNot set
QA Service Level1 (Verified on 10/11/2021)

Sample Information

Sample Taken Date10/26/2021 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/28/2021
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 welded hoops From where was the sample collectedSupplier
First name of sampler or witnessed byRyan Last name of sampler or witnessed byParr
Title of samplerASI Telephone number of sampler510-385-5910
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameConco Reinforcing Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB373-101-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateService Rebar Heat Number(s)350021157
Hoop Manufacturer Lot Number(s)H11 Material Standard CodeASTM A615
Material Grade60 Rebar Size#8
Diameter of Hoop5'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2021-10-26-6
DIME Test ID: 2021-10-26-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-11-01

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 10/29/2021
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11H118/25mm0.7977760.6498431Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 11/1/2021