Summary for Test 2021-10-22-16-4

Test performed: CTM 301-March 2000

Project Information

Project IdentifiersProject ID: 215424
DEA: 024G4404
EFIS: 0214000013
DIST-CO-RTE-PM02-SIS-3-38.0/38.6
Award Date04/05/2021
Closeout Date08/14/2023
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD
QA Service Level1 (Verified on 01/19/2021)

Sample Information

Sample Taken Date10/22/2021 Sample Unique Key16
Date that the sample was received by the laboratory/organization performing the testing10/25/2021 Sample typeDepartment Acceptance
A brief description of the sampleClass 2 Aggregate Base The quantity of what the sample constitutes2 Bags
From where was the sample collectedManufacturer First name of sampler or witnessed byDanny
Last name of sampler or witnessed byHansen Title of samplerConsultant
Telephone number of sampler Laboratory sample identificationD78965
Linked DIME Sample ID The fabricator/manufacturer/facility nameCustom Crushing
Transportation Laboratory (TL) Number815552 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)custom crushing
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberunk A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled02 SIS 3 38 to 38 6 Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-10-22-16
DIME Test ID: 2021-10-22-16-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2021-10-28

Test Results


How will the R value be determined?: By stabilometer
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 10/28/2021
As Received Gradation, Percent Passing 3 in. sieve: 100 %
As Received Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 in. sieve: 100 %
As Received Gradation, Percent Passing 3/4 in. sieve: 99 %
As Received Gradation, Percent Passing 1/2 in. sieve: 85 %
As Received Gradation, Percent Passing 3/8 in. sieve: 72 %
As Received Gradation, Percent Passing #4 sieve: 46 %
As Received Gradation, Percent Passing #8 sieve: 32 %
As Received Gradation, Percent Passing #16 sieve: 24 %
As Received Gradation, Percent Passing #30 sieve: 19 %
As Received Gradation, Percent Passing #50 sieve: 14 %
As Received Gradation, Percent Passing #100 sieve: 10 %
As Received Gradation, Percent Passing #200 sieve: 6.9 %
As Used Gradation, Percent Passing 3 in. sieve: 100 %
As Used Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 86 %
As Used Gradation, Percent Passing 3/8 in. sieve: 73 %
As Used Gradation, Percent Passing #4 sieve: 46 %
As Used Gradation, Percent Passing #8 sieve: 32 %
As Used Gradation, Percent Passing #16 sieve: 24 %
As Used Gradation, Percent Passing #30 sieve: 19 %
As Used Gradation, Percent Passing #50 sieve: 14 %
As Used Gradation, Percent Passing #100 sieve: 10 %
As Used Gradation, Percent Passing #200 sieve: 7 %
Horizontal pressure (specimen 1): 0.1 MPa
Displacement (specimen 1): 4.89
Horizontal pressure (specimen 2): 0.12 MPa
Displacement (specimen 2): 5.2
Horizontal pressure (specimen 3): 0.12 MPa
Displacement (specimen 3): 5.51
R value (specimen 1): 83.6
R value (specimen 2): 79.7
R value (specimen 3): 78.7
R value: 79
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/28/2021 ✔