Summary for Test 2021-10-26-13-5

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 215753
DEA: 050N72U4
EFIS: 0520000169
DIST-CO-RTE-PM05-SB-101-4.4/R7.7
Award Date06/05/2021
Closeout DateNot set
Work DescriptionPlease cc Office Engineer Ni Nyoman Paul on reports sent to RE and SR. Construct High Occupancy Vehicle (HOV) lanes on U.S. Route 101 and rehabilitation - Segment 4B.
Location Description101 freeway in Summerland, CA
QA Service Level1 (Verified on 05/06/2021)

Sample Information

Sample Taken Date10/26/2021 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing10/27/2021 Sample typeQuality Control
A brief description of the samplePCC The quantity of what the sample constitutesOne box girder
From where was the sample collectedManufacturer First name of sampler or witnessed byRoberto
Last name of sampler or witnessed byReyes Title of samplerQC Technician
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCon-Fab California, LLC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameArroyo Paredon Bridge
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSCC-S95-0F
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1873
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of truck chute Where the material sample would have been placed if not sampledbox girder
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-10-26-13
DIME Test ID: 2021-10-26-13-5
Testing Lab: Con-Fab California Corporation - Shafter
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-10-27

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Roberto Reyes Perez
Date of test: 10/27/2021
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 29.9 lb
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 170520 lb
Maximum load on cylinder 2: 169305 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 0 days
Age of specimen in hours: 16 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 6010 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/27/2021