Summary for Test 2021-10-06-27-6

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 213811
DEA: 112T2184
EFIS: 1116000174
DIST-CO-RTE-PM11-SD-5-R38.4/R47.3
Award Date10/29/2018
Closeout Date01/03/2024
Work Description(Alternative Delivery) Construct HOV lanes, soundwalls, culvert rehab, ITS, and bike trail on I-5 . NCC I-5 Highway Improvement.
Location DescriptionIN SAN DIEGO COUNTY IN ENCINITAS AND CARLSBAD FROM SAN ELIJO LAGOON BRIDGE TO 0.3 MILE NORTH OF PALOMAR AIRPORT ROAD OVERCROSSING.
QA Service Level1 (Verified on 12/19/2018)

Sample Information

Sample Taken Date10/06/2021 Sample Unique Key27
Date that the sample was received by the laboratory/organization performing the testing10/19/2021 Sample typeVerification
A brief description of the sampleJMF 1/2" HMA-O-SP The quantity of what the sample constitutes6 Bags of Aggregate
From where was the sample collectedManufacturer First name of sampler or witnessed byDavid
Last name of sampler or witnessed byCarrera Title of sampler
Telephone number of sampler Laboratory sample identification0596O-21
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Otay
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-37-0035::CHULA VISTA
The fabricator's/manufacturer's product name for the sample1/2 HMA-O-SP The fabricator/manufacturer designation for the sample
The plant number326114 Otay SJR A detailed description of where the material sample was collectedBelt Cut at Vulcan Otay
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-10-06-27
DIME Test ID: 2021-10-06-27-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2021-10-25

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 10/20/2021
Clay Level (Test 1): 7.4
Sand Level (Test 1): 3.4
Clay Level (Test 2): 7.6
Sand Level (Test 2): 3.6
Clay Level (Test 3): 7.5
Sand Level (Test 3): 3.5
Sand Equivalent (Test 1): 46
Sand Equivalent (Test 2): 48
Sand Equivalent (Test 3): 47
Sand Equivalent: 47
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/25/2021 ✔