Summary for Test 2021-10-05-7-8

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Award Date05/01/2019
Closeout Date02/22/2024
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date10/05/2021 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/20/2021
Sample typeQuality Assurance A brief description of the sample3/4" F1554 Gr. 55 All thread rod
The quantity of what the sample constitutes800 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler3854470624
Laboratory sample identificationna Linked DIME Sample IDna
The fabricator/manufacturer/facility nameUniversal Industrial Sales, Inc Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-176-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)120203163961 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt SpecificationF1554 gr 55
Bolt Length(s)10 1/2" Nut Specificationna
Washer Specificationna FinishHDG
Diameter/Size3/4" Bolt Mfg. Lot Numberna
Rocap Test Requirement(s)na Lubricant Requirements(s)na

Test Details

DIME Sample ID: 2021-10-05-7
DIME Test ID: 2021-10-05-7-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-10-28

Test Results


Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 10/22/2021
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 120203163961
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: YELLOW
Size: .75 in
Bolt Length: 10.5 in
Measurement Average: 8.36 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/28/2021