Summary for Test 2021-10-20-21-1

Test performed: ASTM F606-14

Project Information

Project IdentifiersProject ID: 213521
DEA: 050L7234
EFIS: 0515000099
DIST-CO-RTE-PM05-SLO-58-3.08
Award Date06/25/2020
Closeout Date08/23/2023
Work DescriptionTROUT CREEK BRIDGE REPLACEMENT
Location DescriptionIN SAN LUIS OBISPO COUNTY ON HWY 58 EAST OF SANTA MARGARITA AT TROUT CREEK BRIDGE (BR NO. 49-0091).
QA Service Level1 (Verified on 09/30/2019)

Sample Information

Sample Taken Date10/20/2021 Sample Unique Key21
Date that the sample was received by the laboratory/organization performing the testing10/20/2021 Sample typeQuality Assurance
A brief description of the sampleA449 ATR with Coupling Nut The quantity of what the sample constitutes1
From where was the sample collectedJob Site First name of sampler or witnessed byAlex
Last name of sampler or witnessed byMartinez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBSMI
Transportation Laboratory (TL) NumberC918914 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)10648850 Nut Mfg. Lot Number(s)S01210302H
Washer Mfg. Lot Number(s) Bolt SpecificationNone
Bolt Length(s) Nut SpecificationA563 Coupling Nut
Washer SpecificationNone FinishF2329
Diameter/Size Bolt Mfg. Lot Number2103153-20
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2021-10-20-21
DIME Test ID: 2021-10-20-21-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2021-10-26

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/22/2021
UTM: 400kip
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11UNC 7/8 0.4626298328013624712284556755Nut Broke in Half

General comments (publicly viewable) (Max 1000 characters): Nut Broke in Half
Test Graph
Source: Bluehill Data Point File

Test was verified on 10/26/2021 ✔