Summary for Test 2021-10-20-21-1
Test performed: ASTM F606-14Project Information
| Project Identifiers | Project ID: 213521 DEA: 050L7234 EFIS: 0515000099 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-58-3.08 |
| Award Date | 06/25/2020 |
| Closeout Date | 08/23/2023 |
| Work Description | TROUT CREEK BRIDGE REPLACEMENT |
| Location Description | IN SAN LUIS OBISPO COUNTY ON HWY 58 EAST OF SANTA MARGARITA AT TROUT CREEK BRIDGE (BR NO. 49-0091). |
| QA Service Level | 1 (Verified on 09/30/2019) |
Sample Information
| Sample Taken Date | 10/20/2021 | Sample Unique Key | 21 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/20/2021 |
| Sample type | Quality Assurance | A brief description of the sample | A449 ATR with Coupling Nut |
| The quantity of what the sample constitutes | 1 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Alex | Last name of sampler or witnessed by | Martinez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | BSMI | Transportation Laboratory (TL) Number | C918914 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 10648850 | Nut Mfg. Lot Number(s) | S01210302H |
| Washer Mfg. Lot Number(s) | Bolt Specification | None | |
| Bolt Length(s) | Nut Specification | A563 Coupling Nut | |
| Washer Specification | None | Finish | F2329 |
| Diameter/Size | Bolt Mfg. Lot Number | 2103153-20 | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2021-10-20-21
DIME Test ID: 2021-10-20-21-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2021-10-26
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/22/2021
UTM: 400kip
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | UNC 7/8 | 0.462 | 62983 | 280 | 136247 | 122845 | 56755 | Nut Broke in Half |
General comments (publicly viewable) (Max 1000 characters): Nut Broke in Half
Test Graph
Source: Bluehill Data Point FileTest was verified on 10/26/2021 ✔