Summary for Test 2021-09-20-54-3

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 215414
DEA: 101J2104
EFIS: 1018000144
DIST-CO-RTE-PM10-SJ-99-9.4/15.0
Award Date02/23/2021
Closeout Date08/26/2022
Work DescriptionPLACE RHMA, COLD PLANE ASPHALT CONCRETE, TRAFFIC STRIPING.
Location DescriptionSAN JOAQUIN COUNTY IN AND NEAR STOCKTON FROM 0.2 MILE NORTH OF LATHROP ROAD OVERCROSSING TO 0.3 MILE NORTH OF ARCH ROAD UNDERCROSSING
QA Service Level1 (Verified on 02/01/2021)

Sample Information

Sample Taken Date09/20/2021 Sample Unique Key54
Date that the sample was received by the laboratory/organization performing the testing10/07/2021 Sample typeDepartment Acceptance
A brief description of the samplePG 64-16 The quantity of what the sample constitutes1 can, NO TEST 9/27, 9/29
From where was the sample collectedSupplier First name of sampler or witnessed byJ
Last name of sampler or witnessed byKort Title of samplerInspector
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Materials Vernalis
Transportation Laboratory (TL) Number21M6416-920 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierMarathon Petroleum Co. LP - Elk Grove CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2021-09-20-54
DIME Test ID: 2021-09-20-54-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-10-22

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 10/14/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 39.431 kPa
Phase Angle (δ) (for the 10 cycles): 52.1 degree
Complex Modulus (G*) (for the 10 measurements): 3942.624 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 3111 kPa
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specifications PAV

Test was verified on 10/22/2021 ✔