Summary for Test 2021-10-07-8-2

Test performed: ASTM C39-18

Project Information

Project IdentifiersProject ID: 209820
DEA: 04297634
EFIS: 0415000040
COOP: 042548
DIST-CO-RTE-PM04-ALA-84,680-17.9/21
Award Date02/19/2021
Closeout DateNot set
Work DescriptionROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION.
Location DescriptionALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84
QA Service Level1 (Verified on 11/04/2019)

Sample Information

Sample Taken Date10/07/2021 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing10/08/2021 Sample typeQuality Control
A brief description of the sample(8) 4x8 concrete cylinders The quantity of what the sample constitutes1 days production
From where was the sample collectedManufacturer First name of sampler or witnessed byWally
Last name of sampler or witnessed byBucaneg Title of samplerQC Technician
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameForterra Pipe and Precast, Florin Rd
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameDrainage System W1
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numbermix 5
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1007
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedconveyor belt Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-10-07-8
DIME Test ID: 2021-10-07-8-2
Testing Lab: Rinker Materials
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-10-18

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Joe Buckley
Date of test: 10/14/2021
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Maximum load on cylinder 1: 67000 lb
Maximum load on cylinder 2: 67120 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Compressive strength (to nearest 10 psi): 5340 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/18/2021 ✔