Summary for Test 2021-09-27-4-4
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 213411 DEA: 030H10U4 EFIS: 0317000246 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-5-9.7/24.9 |
| Award Date | 05/01/2019 |
| Closeout Date | 02/22/2024 |
| Work Description | Not set |
| Location Description | Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct |
| QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
| Sample Taken Date | 09/27/2021 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/30/2021 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 rocap | The quantity of what the sample constitutes | 800 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Lund | Title of sampler | CT METS QA INSPECTOR |
| Telephone number of sampler | 3854470624 | Laboratory sample identification | na |
| Linked DIME Sample ID | na | The fabricator/manufacturer/facility name | Universal Industrial Sales, Inc |
| Transportation Laboratory (TL) Number | na | Inspector Lot Number from the Transportation Laboratory (TL) Form | B390-168-21 |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0143206 |
|---|---|---|---|
| Heat Number(s) | 10656750, 166575, 295008 | Nut Mfg. Lot Number(s) | 23994-166575 |
| Washer Mfg. Lot Number(s) | 972 | Bolt Specification | A325 |
| Bolt Length(s) | 3-1/2" | Nut Specification | A563-DH |
| Washer Specification | F436 | Finish | Mechanical Galvanize |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | BM0853 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Wax and Dye | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2021-09-27-4
DIME Test ID: 2021-09-27-4-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-10-14
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/11/2021
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 2 | 23994-166575 | 52928 | A563 | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 10/14/2021 ✔