Summary for Test 2021-10-11-1-1
Test performed: AASHTO T336-15Project Information
Project Identifiers | Project ID: 99999 DEA: 0322222 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 10/11/2021 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/11/2021 |
Sample type | Quality Assurance | A brief description of the sample | concrete |
The quantity of what the sample constitutes | 90 Cy | From where was the sample collected | Job Site |
First name of sampler or witnessed by | John | Last name of sampler or witnessed by | O'Mara |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | jomara facility | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 123 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 123 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Job site | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-10-11-1
DIME Test ID: 2021-10-11-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: AASHTO T336-15: Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete
Test Release Date: 2021-10-11
Test Results
Input Type: Measured
Tester's full name: John OMara
Date of test: 10/11/2021
Specimen diameter: 150 mm
Specimen length L₀: 300 mm
Frame Cf: 0 mm/mm/°C
Temperature T₁: 21.111 °C
Temperature T₂: 26.667 °C
Temperature T₃: 32.222 °C
Length L₁: 300 mm
Length L₂: 300.018 mm
Length L₃: 300.036 mm
Aggregate Type: Granite
ΔT₁=T₂-T₁: 5.556 °C
ΔT₂=T₃-T₂: 5.555 °C
ΔL₁=L₂-L₁: 0.018 mm
ΔL₂=L₃-L₂: 0.018 mm
ΔLf₁=Cf*L₀*ΔT₁: 0 mm
ΔLf₂=Cf*L₀*ΔT₂: 0 mm
ΔLa₁=Lm₁+ΔT₁: 0.018 mm
ΔLa₂=Lm₂+ΔT₂: 0.018 mm
CTE₁=ΔLa₁/ΔL₀/ΔT₁: 0.000010799 mm
CTE₂=ΔLa₂/ΔL₀/ΔT₂: 0.000010801 mm
Average CTE: 0.000010800 mm/mm/°C
Average CTE: 0.000006 in/in/°F
General comments (publicly viewable) (Max 1000 characters): DIME Long Term Planning - Testing - Assume rigid frame
Test was verified on 10/11/2021 ✔