Summary for Test 2021-09-20-39-1

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 214492
DEA: 033F5404
EFIS: 0313000136
DIST-CO-RTE-PM03-SAC-99,160-4.5/5.7,R44.5
Award Date01/24/2020
Closeout Date07/28/2022
Work DescriptionFURNISH PRECAST PRESTRESSED CONCRETE SLAB & PLACE STRUCTURAL CONCRETE.
Location DescriptionSACRAMENTO COUNTY NEAR GALT ON ROUTE 99 FROM NORTH OF MINGO ROAD TO SOUTH OF ARNO ROAD OVERCROSSING AND IN SACRAMENTO ON ROUTE 160 AT AMERICAN RIVER BRIDGE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date09/20/2021 Sample Unique Key39
Date that the sample was received by the laboratory/organization performing the testing10/01/2021 Sample typeDepartment Acceptance
A brief description of the sample64-10 The quantity of what the sample constitutes1 can
From where was the sample collectedManufacturer First name of sampler or witnessed byJon
Last name of sampler or witnessed byBlumer Title of samplerTeichert tech
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Perkins Batch Plant, from Valero Benecia
Transportation Laboratory (TL) Numberc850283 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
ModifiedNo Lot number1
Sublot number1 Tank number
Time of sample HMA SupplierTeichert Perkins Batch Plant
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2021-09-20-39
DIME Test ID: 2021-09-20-39-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-10-12

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 10/06/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.184 kPa
Phase Angle (δ) (for the 10 cycles): 86.8 degree
Complex Modulus (G*) (for the 10 measurements): 1.532 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.53 kPa
General comments (publicly viewable) (Max 1000 characters): ORG

Test was verified on 10/12/2021 ✔