Summary for Test 2021-08-19-65-1
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 215572 DEA: 032G1104 EFIS: 0320000230 |
---|---|
DIST-CO-RTE-PM | 03-GLE-162-66.6/76.3 |
Award Date | 05/06/2021 |
Closeout Date | 06/27/2022 |
Work Description | PLACE RHMA AND COLD IN-PLACE RECYCLE. |
Location Description | GLENN COUNTY IN AND NEAR WILLOWS FROM 0.2 MILE EAST OF N SHASTA STREET TO 1.0 MILE EAST OF ROAD X |
QA Service Level | 1 (Verified on 03/22/2021) |
Sample Information
Sample Taken Date | 08/19/2021 | Sample Unique Key | 65 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/01/2021 |
Sample type | Department Acceptance | A brief description of the sample | 64-16 |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brad | Last name of sampler or witnessed by | M |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | KRC Orland | Transportation Laboratory (TL) Number | c779899 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | 1 |
Sublot number | 11 | Tank number | |
Time of sample | HMA Supplier | KRC Orland | |
Certified Asphalt Supplier | Marathon Petroleum Co. LP - Elk Grove CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-19-65
DIME Test ID: 2021-08-19-65-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-10-11
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 10/05/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.160 kPa
Phase Angle (δ) (for the 10 cycles): 87.7 degree
Complex Modulus (G*) (for the 10 measurements): 1.334 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.34 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications ORG
Test was verified on 10/11/2021 ✔