Summary for Test 2021-09-13-37-6
Test performed: AASHTO T51-13Project Information
| Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 09/13/2021 | Sample Unique Key | 37 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 09/13/2021 |
| Sample type | Quality Control | A brief description of the sample | Tank 0150 |
| The quantity of what the sample constitutes | 1 of 2 | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | PAT OPS | Last name of sampler or witnessed by | PAT OPS |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 6416-091321 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Pittsburg, CA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero-NuStar PAT - Pittsburg CA | Multigrade | Yes |
| Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-09-13-37
DIME Test ID: 2021-09-13-37-6
Testing Lab: Valero-NuStar PAT - Pittsburg
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-10-06
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Calculated
Tester's full name: APART
Date of test: 09/16/2021
Ductility of test #1 (D1): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): Submitted from ASCP bulk upload. average of 3 tests
Test was verified on 10/6/2021 ✔