Summary for Test 2021-09-13-37-1
Test performed: AASHTO T48-18Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 09/13/2021 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 09/13/2021 |
Sample type | Quality Control | A brief description of the sample | Tank 0150 |
The quantity of what the sample constitutes | 1 of 2 | From where was the sample collected | Supplier |
First name of sampler or witnessed by | PAT OPS | Last name of sampler or witnessed by | PAT OPS |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 6416-091321 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Pittsburg, CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Valero-NuStar PAT - Pittsburg CA | Multigrade | Yes |
Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-09-13-37
DIME Test ID: 2021-09-13-37-1
Testing Lab: Valero-NuStar PAT - Pittsburg
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2021-10-06
Test Results
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Calculated
Tester's full name: APART
Date of test: 09/16/2021
Observed Flash Point: 312 C
Ambient Barometric Pressure: 752.2 mmHg
Cleveland Open-Cup Flash Point in Celsius: 312 C
General comments (publicly viewable) (Max 1000 characters): Submitted from ASCP bulk upload.
Test was verified on 10/6/2021 ✔