Summary for Test 2021-08-12-49-2
Test performed: AASHTO T51-13Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 08/12/2021 | Sample Unique Key | 49 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/17/2021 |
Sample type | Verification | A brief description of the sample | 64-16 Asphalt Binder |
The quantity of what the sample constitutes | 1 quart can, split sample | From where was the sample collected | Supplier |
First name of sampler or witnessed by | na | Last name of sampler or witnessed by | na |
Title of sampler | COC Program | Telephone number of sampler | |
Laboratory sample identification | PG641681221KF40 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Albina Klamath Falls | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | 40 | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Albina Asphalt - Klamath Falls Plant - Klamath Falls OR | Multigrade | Yes |
Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-12-49
DIME Test ID: 2021-08-12-49-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-10-08
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 10/04/2021
Ductility of test #1 (D1): 150 cm
Ductility of test #2 (D2): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): 150+
Test was verified on 10/8/2021 ✔