Summary for Test 2021-09-28-5-10

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 214300
DEA: 07343404
EFIS: 0718000018
DIST-CO-RTE-PM07-LA-39-31.2
Award Date10/30/2019
Closeout Date05/06/2024
Work DescriptionIN LOS ANGELES COUNTY, ON ROUTE 39 AT NORTH FORK SAN GABRIEL RIVER BRIDGE (BR. NO. 53-3069) REPLACE BRIDGE
Location DescriptionIN LOS ANGELES COUNTY ABOUT 19 MILES NORTH OF AZUSA AT NORTH FORK SAN GABRIEL RIVER BRIDGE
QA Service Level1 (Verified on 12/20/2019)

Sample Information

Sample Taken Date09/28/2021 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing09/29/2021 Sample typeQuality Assurance
A brief description of the sample.6in Prestressing Strand The quantity of what the sample constitutes43
From where was the sample collectedManufacturer First name of sampler or witnessed byDon
Last name of sampler or witnessed byHiranaga Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSumiden Wire
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s) Number of Coils
Group Number10982 Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0541621, S0541521, S0225047, S0225050, S0225049 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2021-09-28-5
DIME Test ID: 2021-09-28-5-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2021-10-04

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/30/2021
UTM: 120kip
Temperature: 72 f
Extensometers: no data
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0225049S379825-40.2186000357074.831.21.6bewing

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 10/4/2021 ✔