Summary for Test 2021-09-23-6-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210673
DEA: 042640F4
EFIS: 0400020132
COOP: 042308A3
DIST-CO-RTE-PM04-SON--
Award Date08/08/2019
Closeout Date02/16/2024
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date09/23/2021 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/24/2021
Sample typeQuality Assurance A brief description of the sample#8 x 5'-2" dia.
The quantity of what the sample constitutes4 Hoops From where was the sample collectedFabricator
First name of sampler or witnessed byOsiel Last name of sampler or witnessed byRamirez
Title of samplerQA Inspector Telephone number of sampler5599740870
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL123-108-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1201033913
Hoop Manufacturer Lot Number(s)Lot 3 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop5'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Company Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2021-09-23-6
DIME Test ID: 2021-09-23-6-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-10-01

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/30/2021
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1338/25mm0.7974414.7094196OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 10/1/2021