Summary for Test 2021-09-17-28-8
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 215333 DEA: 120S6604 EFIS: 1221000004 |
---|---|
DIST-CO-RTE-PM | 12-ORA-91-R16.6/R17.0 |
Award Date | 05/18/2021 |
Closeout Date | 08/11/2022 |
Work Description | COLD PLANE AC PAVEMENT AND PLACE PRECAST CONCRETE PAVEMENT. |
Location Description | ORANGE COUNTY IN YORBA LINDA FROM W91-S241/91 CONNECTOR SEPARATION TO 0.6 MILE EAST OF GYPSUM CANYON ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 02/22/2021) |
Sample Information
Sample Taken Date | 09/17/2021 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/23/2021 |
Sample type | Quality Assurance | A brief description of the sample | .5 Prestressing Strand |
The quantity of what the sample constitutes | 25 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | ||
Group Number | 10981 | Strand Diameter | .5 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0224419, S0224420, S0224422, S0224417, S0224425, S0224416, S0224418, S0224421 | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2021-09-17-28
DIME Test ID: 2021-09-17-28-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2021-10-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/29/2021
UTM: 120kip
Temperature: 72 f
Extensometers: no data
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0224425 | S131939-5 | 0.151 | 43005 | 39789.2 | 28.7 | 1.77 | bewing |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 10/4/2021 ✔