Summary for Test 2021-09-20-1-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 215486 DEA: 040A0204 EFIS: 0400000129 |
---|---|
DIST-CO-RTE-PM | 04-SON-1-15-15.7 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Construct roadway and bridge with structural concrete and CIDH piling |
Location Description | District-County-Route-Post Mile: 04-Son-1-R15.0/R15.7 |
QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
Sample Taken Date | 09/20/2021 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/28/2021 |
Sample type | Quality Control | A brief description of the sample | 5/8 x 3-1/2 a325 boilts |
The quantity of what the sample constitutes | 95 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Oscar | Last name of sampler or witnessed by | Vizcaino |
Title of sampler | Telephone number of sampler | 6787558969 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | St Louis Screw and Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0145880 |
---|---|---|---|
Heat Number(s) | 20378880 | Nut Mfg. Lot Number(s) | 32805-6215177505 |
Washer Mfg. Lot Number(s) | D9402 | Bolt Specification | A-325 |
Bolt Length(s) | 3-1/2" | Nut Specification | A563 |
Washer Specification | F436 | Finish | Mechanical B695 |
Diameter/Size | 5/8" | Bolt Mfg. Lot Number | M4588 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-09-20-1
DIME Test ID: 2021-09-20-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-10-01
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/29/2021
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1 | 039674 | 31134 | A325 | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 10/1/2021 ✔