Summary for Test 2021-07-08-57-6

Test performed: AASHTO T324-14

Project Information

Project IdentifiersProject ID: 215656
DEA: 032G0604
EFIS: 0320000192
DIST-CO-RTE-PM03-SAC-5736-
Award Date05/26/2021
Closeout Date05/11/2022
Work DescriptionREMOVE AND REPLACE CL2 AGGREGATE BASE AND HMA (TYPE A).
Location DescriptionSACRAMENTO COUNTY IN SACRAMENTO AT THE NORTHGATE MAINTENANCE STATION AT 3940 ROSIN COURT
QA Service Level1 (Verified on 04/19/2021)

Sample Information

Sample Taken Date07/08/2021 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/01/2021
Sample typeVerification A brief description of the sample1/2" HMA-A
The quantity of what the sample constitutes12 Boxes of mix From where was the sample collectedSupplier
First name of sampler or witnessed by? Last name of sampler or witnessed by?
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGeorge Reed Drum Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2021-07-08-57
DIME Test ID: 2021-07-08-57-6
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2021-09-24

Test Results


Input Type: Measured
Tester's full name: Jeff Herbert
Date of test: 09/06/2021
HMA Production: Field Plant Produced
Specified number of passes at 12.7 mm: 15000
Specified number of passes at inflection point: 10000
Type and Amount of Anti-Stripping Additive: N/A
Compaction Method: SGC Cylindrical Specimen
Test Temperature: 122 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 4.72 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 7.1 mm
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 25000
Impression at specified number of passes average: 6 mm
General comments (publicly viewable) (Max 1000 characters): JMF 21-036

Test was verified on 9/24/2021