Summary for Test 2021-09-21-5-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 215075
DEA: 060Q9104
EFIS: 0614000005
DIST-CO-RTE-PM06-TUL-99-19.2/19.8
Award Date09/25/2020
Closeout Date05/11/2023
Work DescriptionBRIDGE DECK AND OUTSIDE GIRDER REPLACEMENT.
Location DescriptionTULARE COUNTY NEAR TIPTON FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF AVENUE 152 OVERCROSSING
QA Service Level1 (Verified on 07/28/2020)

Sample Information

Sample Taken Date09/21/2021 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing09/21/2021 Sample typeQuality Assurance
A brief description of the sampleCoupler The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed bySuk
Last name of sampler or witnessed byThun Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNucor HRC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)Z82834A 73117653 Rebar Heat Number(s)3500014896
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-09-21-5
DIME Test ID: 2021-09-21-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-09-23

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/22/2021
UTM: 2000kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 11/36mm101.5614725794396Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 9/23/2021 ✔