Summary for Test 2021-07-12-54-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 215032 DEA: 030H5204 EFIS: 0315000202 |
---|---|
DIST-CO-RTE-PM | 03-ED-50-0.0/80.4 |
Award Date | 08/13/2020 |
Closeout Date | 07/26/2023 |
Work Description | INSTALL CMS, CAMERA SYSTEMS AND TMS ELEMENTS. |
Location Description | EL DORADO COUNTY AT VARIOUS LOCATIONS FROM THE SACRAMENTO COUNTY LINE TO CALIFORNIA/NEVADA STATE LINE |
QA Service Level | 1 (Verified on 07/20/2020) |
Sample Information
Sample Taken Date | 07/12/2021 | Sample Unique Key | 54 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/12/2021 |
Sample type | Quality Control | A brief description of the sample | 1 x #4 Aggregates |
The quantity of what the sample constitutes | 1 Day | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Kristipher | Last name of sampler or witnessed by | Weaver |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Syar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 2297 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | CT072CR8WA | Lot number | |
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-07-12-54
DIME Test ID: 2021-07-12-54-1
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2022-04-13
Test Results
What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Todd Strait
Date of test: 07/13/2021
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 99 %
Cumulative percent passing the 3/4 in. sieve: 86 %
Cumulative percent passing the 1/2 in. sieve: 28 %
Cumulative percent passing the 3/8 in. sieve: 6 %
Cumulative percent passing the #4 sieve: 1 %
Cumulative percent passing the #8 sieve: 1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/13/2022 ✔