Summary for Test 2021-08-13-35-6

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215605
DEA: 040W3904
EFIS: 0420000212
DIST-CO-RTE-PM04-CC-160-L1.1/0.6
Award Date05/10/2021
Closeout Date06/29/2023
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE HMA (A).
Location DescriptionCONTRA COSTA COUNTY IN ANTIOCH FROM 0.2 MILE SOUTH OF MAIN STREET TO 0.1 MILE NORTH OF WILBUR AVENUE
QA Service Level1 (Verified on 04/12/2021)

Sample Information

Sample Taken Date08/13/2021 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/13/2021
Sample typeVerification A brief description of the sample25 Boxes-Hot Mix Asphalt
The quantity of what the sample constitutes25 Boxes-Hot Mix Asphalt From where was the sample collectedManufacturer
First name of sampler or witnessed byClint Last name of sampler or witnessed byRogers
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameABM ANTIOCH Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-13-35
DIME Test ID: 2021-08-13-35-6
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-09-15

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Randy Cortez
Date of test: 08/23/2021
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2042.7 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1922.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.50 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 5.39 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/15/2021