Summary for Test 2021-08-19-61-6
Test performed: AASHTO T335-09r13Project Information
Project Identifiers | Project ID: 214985 DEA: 04269804 EFIS: 0412000159 |
---|---|
DIST-CO-RTE-PM | 04-CC-242-R0.0/R1.6 |
Award Date | 12/04/2020 |
Closeout Date | 12/08/2022 |
Work Description | PRECAST JOINTED CONC PVMT, INDIVIDUAL SLAB REPLACEMENT, HMA & RHMA. |
Location Description | CONTRA COSTA COUNTY IN CONCORD FROM ROUTE 242/680 SEPARATION TO BUCHANAN FIELD VIADUCT |
QA Service Level | 1 (Verified on 10/19/2020) |
Sample Information
Sample Taken Date | 08/19/2021 | Sample Unique Key | 61 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2021 |
Sample type | Verification | A brief description of the sample | 5 Bags of Aggregate |
The quantity of what the sample constitutes | 5 Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | ignacio | Last name of sampler or witnessed by | Areihiga |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | County Asphalt Martinez | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-07-0003 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | County Asphalt Martinez | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-19-61
DIME Test ID: 2021-08-19-61-6
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2021-09-15
Test Results
Method: 2 - Individual Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Nicholas Shelly
Date of test: 08/19/2021
Weighted average percentage of fractured, coarse, 2 faced particles: 100 %
Weighted average percentage of fractured, coarse, 1 faced particles: 96 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/15/2021 ✔