Summary for Test 2021-08-04-38-6

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/04/2021 Sample Unique Key38
Date that the sample was received by the laboratory/organization performing the testing09/07/2021 Sample typeVerification
A brief description of the sampleJMF 1/2" RHMA-G-SP 1.0% LAS The quantity of what the sample constitutes4 Bags of Combined Aggregate
From where was the sample collectedManufacturer First name of sampler or witnessed byRMA
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification0520G-21
Linked DIME Sample ID The fabricator/manufacturer/facility nameAll American Asphalt-Corona
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number106836 A detailed description of where the material sample was collectedBelt Cut at All American Corona Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-04-38
DIME Test ID: 2021-08-04-38-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-09-21

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 09/10/2021
Bulk dry specific gravity: 2.657
Average uncompacted voids: 46.4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/21/2021