Summary for Test 2021-08-16-47-3
Test performed: ASTM D5329-16Project Information
| Project Identifiers | Project ID: 215406 DEA: 043Q4204 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-1-9.1/16.1 |
| Award Date | 02/18/2021 |
| Closeout Date | 05/26/2022 |
| Work Description | COLD PLANE AC PAVEMENT AND PLACE RHMA (GAP GRADED). |
| Location Description | SONOMA COUNTY IN AND NEAR BODEGA BAY FROM DORAN PARK ROAD TO 0.8 MILE NORTH OF SCOTTY CREEK BRIDGE |
| QA Service Level | 1 (Verified on 01/19/2021) |
Sample Information
| Sample Taken Date | 08/16/2021 | Sample Unique Key | 47 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/07/2021 | Sample type | Department Acceptance |
| A brief description of the sample | PG64-16 Rubber Blend | The quantity of what the sample constitutes | 1 can |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Nick |
| Last name of sampler or witnessed by | Hall | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Syar Todd Drum | |
| Transportation Laboratory (TL) Number | c044753 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | 1 |
| Sublot number | 1 | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-16-47
DIME Test ID: 2021-08-16-47-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-09-15
Test Results
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 09/14/2021
Temperature: 25 C
Ball Penetration (P1): 1 mm
Final Dial reading (F1): 60 mm
Ball Penetration (P2): 1 mm
Final Dial reading (F2): 64 mm
Ball Penetration (P3): 1 mm
Final Dial reading (F3): 64 mm
Resilience 1: 41 %
Resilience 2: 37 %
Resilience 3: 37 %
Average Resilience: 38 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 9/15/2021 ✔