Summary for Test 2021-09-07-7-9
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 55556 DEA: OCR EFIS: OCR |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Oregon Corp. Research. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 09/07/2021 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/07/2021 |
Sample type | Proficiency | A brief description of the sample | PG70-34 |
The quantity of what the sample constitutes | 1 of 1 can | From where was the sample collected | Source |
First name of sampler or witnessed by | OREGON COOP | Last name of sampler or witnessed by | OREGON COOP |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Idaho Asphalt Supply, Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-22 |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | SAMPLE 317 | |
Certified Asphalt Supplier | Oregon Corp - Salem OR | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-09-07-7
DIME Test ID: 2021-09-07-7-9
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-09-23
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 09/14/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.190 kPa
Phase Angle (δ) (for the 10 cycles): 52.9 degree
Complex Modulus (G*) (for the 10 measurements): 1.581 kPa
Test Temperature (Specimen 1): 70.0 C
Dynamic Shear, G*/sin(δ): 1.98 kPa
General comments (publicly viewable) (Max 1000 characters): ORIG2ND
Test was verified on 9/23/2021 ✔