Summary for Test 2021-09-02-30-1

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
Permit Numbers: 0823NMC0369
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Award Date03/11/2020
Closeout Date06/05/2024
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
QA Service Level1 (Verified on 09/16/2020)

Sample Information

Sample Taken Date09/02/2021 Sample Unique Key30
Date that the sample was received by the laboratory/organization performing the testing09/03/2021 Sample typeDepartment Acceptance
A brief description of the sampleConcrete beams The quantity of what the sample constitutes4 Beams
From where was the sample collectedJob Site First name of sampler or witnessed byJames / Kevin
Last name of sampler or witnessed byBurton / Oluoha Title of sampler
Telephone number of sampler Laboratory sample identification1JA1, 1JA2, 1JB1, 1JB2
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex, Fontana
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1605762
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedTTI
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedOn Job Site at Concrete Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-09-02-30
DIME Test ID: 2021-09-02-30-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2021-09-13

Test Results


Number of specimens:
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: k. Talati, R. Osorio
Date of test: 09/12/2021
Identification number: 1JA1
Width of specimen: 5.9 inch
Depth of specimen: 6.0 inch
Span length of specimen: 18 inch
Maximum load applied: 6720 lb
Curing history and apparent moisture condition of the specimen: moist, curing room
If specimen was capped, ground or if leather shims were used: No
Defects in specimen: None
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 590 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/13/2021 ✔