Summary for Test 2021-08-31-20-6

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 215410
DEA: 060U5204
EFIS: 0616000003
DIST-CO-RTE-PM06-MAD-99-R14.0/R14.5,15.1/19.6
Award Date04/01/2021
Closeout Date10/03/2022
Work DescriptionHMA (TYPE A) AND RHMA (GAP GRADED) RESURFACING.
Location DescriptionMADERA COUNTY IN AND NEAR MADERA FROM 0.2 MILE SOUTH OF AVENUE 17 OVERCROSSING TO 0.3 MILE NORTH OF AVENUE 17 OVERCROSSING AND FROM 1.0 MILE NORTH OF AVENUE 17 OVERCROSSING TO 0.9 MILE NORTH OF AVENUE 20 OVERCROSSING
QA Service Level1 (Verified on 01/25/2021)

Sample Information

Sample Taken Date08/31/2021 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/03/2021
Sample typeDepartment Acceptance A brief description of the sampleBINDER
The quantity of what the sample constitutes1 CAN From where was the sample collectedSource
First name of sampler or witnessed byNICK Last name of sampler or witnessed byVULCAN TECH
Title of samplerVULCAN TECH Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSan Joaquin Refinery Transportation Laboratory (TL) NumberC039823
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number1
Sublot number7 Tank number
Time of sample HMA SupplierVULCAN MADERA
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-31-20
DIME Test ID: 2021-08-31-20-6
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-09-14

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 09/09/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 53.736 kPa
Phase Angle (δ) (for the 10 cycles): 60.9 degree
Complex Modulus (G*) (for the 10 measurements): 5372.934 kPa
Test Temperature (Specimen 1): 37.0 C
(G*) x sin(δ)=: 4695 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications PAV+3

Test was verified on 9/14/2021