Summary for Test 2021-08-13-35-4
Test performed: AASHTO T324-14Project Information
| Project Identifiers | Project ID: 215605 DEA: 040W3904 EFIS: 0420000212 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-160-L1.1/0.6 |
| Award Date | 05/10/2021 |
| Closeout Date | 06/29/2023 |
| Work Description | COLD PLANE AC PAVEMENT AND PLACE HMA (A). |
| Location Description | CONTRA COSTA COUNTY IN ANTIOCH FROM 0.2 MILE SOUTH OF MAIN STREET TO 0.1 MILE NORTH OF WILBUR AVENUE |
| QA Service Level | 1 (Verified on 04/12/2021) |
Sample Information
| Sample Taken Date | 08/13/2021 | Sample Unique Key | 35 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/13/2021 | Sample type | Verification |
| A brief description of the sample | 25 Boxes-Hot Mix Asphalt | The quantity of what the sample constitutes | 25 Boxes-Hot Mix Asphalt |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Clint |
| Last name of sampler or witnessed by | Rogers | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | ABM ANTIOCH | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2021-08-13-35
DIME Test ID: 2021-08-13-35-4
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2021-09-09
Test Results
Input Type: Measured
Tester's full name: Trevor Hamilton
Date of test: 08/23/2021
HMA Production: Field Plant Produced
Specified number of passes at 12.7 mm: 15000
Specified number of passes at inflection point: no data
Type and Amount of Anti-Stripping Additive: NA
Compaction Method: SGC Cylindrical Specimen
Test Temperature: 122 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 1.55 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 2.84 mm
Stripping Inflection Point (Wheel A): 24994
Stripping Inflection Point (Wheel B): 24988
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 15000
Impression at specified number of passes average: 2 mm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/9/2021 ✔