Summary for Test 2021-08-13-34-6
Test performed: AASHTO T304-11Project Information
| Project Identifiers | Project ID: 215605 DEA: 040W3904 EFIS: 0420000212 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-160-L1.1/0.6 |
| Award Date | 05/10/2021 |
| Closeout Date | 06/29/2023 |
| Work Description | COLD PLANE AC PAVEMENT AND PLACE HMA (A). |
| Location Description | CONTRA COSTA COUNTY IN ANTIOCH FROM 0.2 MILE SOUTH OF MAIN STREET TO 0.1 MILE NORTH OF WILBUR AVENUE |
| QA Service Level | 1 (Verified on 04/12/2021) |
Sample Information
| Sample Taken Date | 08/13/2021 | Sample Unique Key | 34 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/13/2021 | Sample type | Verification |
| A brief description of the sample | 3 Bags of Mix Aggregates | The quantity of what the sample constitutes | 3 Bags of Mix Aggregates |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Clint |
| Last name of sampler or witnessed by | Rogers | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | ABM ANTIOCH | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-07-0004 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | ABM CONTINUOUS PLANT | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-13-34
DIME Test ID: 2021-08-13-34-6
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-09-09
Test Results
What test method is performed?: Method A
Input Type: Measured
Tester's full name: David Ordaz
Date of test: 08/18/2021
Mass of measure: 250.8 grams
Bulk dry specific gravity: 2.589
Mass of sample and measure #1: 392.4 grams
Mass of sample and measure #2: 392.6 grams
Volume of cylinder: 100.3 mL
Mass of sample #1: 141.6 grams
Mass of sample #2: 141.8 grams
Uncompacted voids #1: 45.5 %
Uncompacted voids #2: 45.4 %
Average uncompacted voids: 45.5 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/9/2021 ✔