Summary for Test 2015-09-03-9-2

Test performed: ASTM C138-17a

Project Information

Project IdentifiersProject ID: 209141
DEA: 07215954
EFIS: 0700001835
DIST-CO-RTE-PM07-LA-5-0.0/7.6
Award Date04/24/2014
Closeout Date07/14/2022
Work DescriptionWIDENING FREEWAY AND RECONSTRUCT OVERHEAD AND OVERCROSSING STRUCTURES
Location DescriptionLOS ANGELES COUNTY IN LA MIRADA, SANTA FE SPRINGS, NORWALK AND DOWNEY FROM ORANGE COUNTY/LOS ANGELES COUNTY LIMIT LINES TO 0.7 MILE NORTH OF ROUTE 605
QA Service Level1 (Verified on 06/02/2014)

Sample Information

Sample Taken Date09/03/2015 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing09/04/2015 Sample typeQuality Control
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byDavid
Last name of sampler or witnessed byIllescas Title of samplerQC Field Technician
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility namejobsite
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierUnknown Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3-15-STR-001
The truck number from where the sample was collected1996 The batch plant ticket number from where the sample was collected41946
Concrete batch plantSecurity Paving Plant The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedRW 326 Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2015-09-03-9
DIME Test ID: 2015-09-03-9-2
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Test Release Date: 2015-10-23

Test Results


Input Type: Calculated
Tester's full name: David Illescas
Date of test: 09/03/2015
Identification of concrete represented by the sample: RW 326
Volume of the measure: 0.500 ft^3
Density of concrete: 146.9 lb/ft^3
Yield of concrete: no data
Relative yield of the batch: no data
Cement content: no data
Air content: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/23/2015 ✔