Summary for Test 2021-08-26-12-4

Test performed: ASME B1.2-83r01

Project Information

Project IdentifiersProject ID: 215448
DEA: 031G7404
EFIS: 0319000238
DIST-CO-RTE-PM03-SAC-50-Var
Award Date03/12/2021
Closeout Date03/02/2022
Work DescriptionREMOVE BOLTS AND ADD PAINTED STRUCTURAL STEEL PLATES.
Location DescriptionSACRAMENTO COUNTY IN SACRAMENTO AT SACRAMENTO RIVER VIADUCT AND RAMP A4
QA Service Level1 (Verified on 02/19/2021)

Sample Information

Sample Taken Date08/26/2021 Sample Unique Key12
Date that the sample was received by the laboratory/organization performing the testing09/02/2021 Sample typeQuality Assurance
A brief description of the sample7/8 A325 fastener assemblies The quantity of what the sample constitutes20 each
From where was the sample collectedFabricator First name of sampler or witnessed byGreg
Last name of sampler or witnessed byThompson Title of samplerAssociate Steel Inspector
Telephone number of sampler5103767155 Laboratory sample identification
Linked DIME Sample ID2021-08-26-7 The fabricator/manufacturer/facility nameCK Johnson Industries
Transportation Laboratory (TL) Numberc658227 Inspector Lot Number from the Transportation Laboratory (TL) FormB9-041-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)377091A
Heat Number(s)bolt-DL16100943 washer- 209071 nut- 453592B Nut Mfg. Lot Number(s)Nucor- 453592B
Washer Mfg. Lot Number(s)Wrought- 10444 9874 Bolt SpecificationA325
Bolt Length(s)4.5" Nut SpecificationA563DH
Washer SpecificationF436 FinishHDG
Diameter/Size7/8" Bolt Mfg. Lot NumberNucor- 377091A
Rocap Test Requirement(s)yes Lubricant Requirements(s)yes
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2021-08-26-12
DIME Test ID: 2021-08-26-12-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Test Release Date: 2021-09-09

Test Results


Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 09/08/2021
Sample No.: 6A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 453592B
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: DH N
Size: .875 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/9/2021 ✔