Summary for Test 2021-09-01-25-1

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 212496
DEA: 024E4504
EFIS: 0200020286
DIST-CO-RTE-PM02-LAS,MOD-139,299-VAR
Award Date07/28/2020
Closeout Date08/14/2023
Work DescriptionPLACE HMA, REPLACE DRAINAGE, CULVERT, ELECTRICAL AND LIGHTING SYSTEMS.
Location DescriptionLASSEN AND MODOC COUNTIES ON ROUTE 139 AT 0.1 MILE NORTH OF LASSEN COUNTY LINE AND ON ROUTE 299 AT VARIOUS LOCATONS FROM 0.4 MILE WEST OF BOYD HILL LOOKOUT ROAD TO 0.6 MILE EAST OF COUNTY ROAD 87
QA Service Level1 (Verified on 06/06/2017)

Sample Information

Sample Taken Date09/01/2021 Sample Unique Key25
Date that the sample was received by the laboratory/organization performing the testing09/02/2021 Sample typeDepartment Acceptance
A brief description of the sample3/8 inch RAP The quantity of what the sample constitutesPSE 1 bag at 418 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byE.
Last name of sampler or witnessed byChavez Title of samplerMaterials Tester
Telephone number of sampler Laboratory sample identificationD78937
Linked DIME Sample ID2021-09-01-24, 2021-09-01-26 The fabricator/manufacturer/facility nameHat Creek Construction and Materials - Shaw Pit Facility - Lookout, CA
Transportation Laboratory (TL) Number848960 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceHat Creek Construction and Materials, Shaw Pit Facility, Lookout, CA
Aggregate Size3/8 inch Aggregate SourceHat Creek Construction
RAP StockpileContinuous Stockpile Size (tons)Unknown
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2021-09-01-25
DIME Test ID: 2021-09-01-25-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-09-09

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 09/03/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7336.6 grams
Mass of oven-dry sample in air for Sample 1: 1592.2 grams
Mass of container filled with the sample and water for Sample 1: 8294.3 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.509
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/9/2021 ✔